laser therapy Apparatus
"Face-therapist M" APPOINTMENT OF STAFF
1.1 The device is intended for use as a laser source
the visible and infrared range of the spectrum with the aim of carrying out a wide range of procedures
medical rehabilitation, physiotherapy, balneology.
The device provides:
- Speed adjustment and power control of visible light;
- Speed adjustment and power control infrared DC
radiation;
- Installation and monitoring procedures of time;
- Modulation of the radiation;
- Control of radiation dose.
2. SPECIFICATIONS
2.1 The length of the visible light wave "B" - 405-700 nm.
2.2 Wavelength "SP" infrared radiation DC - 701-1050 nm.
2.3 Power output "B" radiation - (5,10,15,20,25,30,35,40,45,50) mVt20%.
2.4 Output Power "FE" radiation - (10,20,30,40,50,60,70,80,90,100) mVt20%.
2.5 "IP" Output power laser radiation pilot not more than 1% mVt20.
2.6 Modulation of the "B" and "SP" radiation - Gts10 0.1-99.9%.
2.7 Radiation Time - 1s ... 99 min 59 sec.
2.8 Radiation Dose - Dzh20 0.01-99.99%.
2.9 Divergence of the radiation beam at the remote end of the handle - no more
0,5rad20%.
2.10 The unit operates on AC 50 Hz ± 1%, and a voltage
220 V ± 10%.
2.11 The power consumed by the device - no more than 10 watts.
2.12 The optical density of laser protective glasses - at least 3 Bel.
2.13 unit weight of not more than 1.5 kg, the unit weight (gross) - less than 2.5 kg.
2.14 Dimensions:
- An electronic unit, mm - 245 × 140 × 75;
- External handle, mm - 180 × 32 × 32;
- Cord length external handle not less than -1500 mm;
- The cord length is not less - 2000 mm.
5. DESIGN AND OPERATION OF THE MACHINE
5.1 Composition of the machine (Annex 3):
- An electronic unit (8);
- External handle (5);
The electronic unit comprises:
- Housing;
- Indicating subunit A1 (3);
- A2 subunit keyboard (4);
- A3 control subunit;
- A4 subunit supply.
5.2 Purpose of controls, display and control:
5.2.1 On the front panel:
Buttons:
POWER - Δ increase, decrease in laser power;
TIME - Δ increase, temporary decrease in the value of the radiation parameters;
FREQUENCY - Δ increase, decrease the value of the laser radiation modulation;
START - the inclusion of the radiation on the typed parameters;
STOP / CLEAR - in the primary pressing - off radiation in the secondary
pressed - Reset settings dialed.
photodiode "CONTROL" (6) - Control of the radiated power;
enable LED control light.
5.2.2 On the front side panel:
Connector for external lever (2);
Fuse F1A 250V
Putting cord 220V 50Hz 10W (1).
5.2.3 On the side of the right pane:
NETWORK switch (7) - switch unit ( "1"), off
unit ( "0").
5.3 Principle of operation
The operating principle of the device is based on the generation of laser radiation
"VRIP" semiconductor lasers and laser modules outrigger arms "BPB"
its output through optical connectors for periphery instrument for the purpose of
delivery of laser radiation to the site of the procedure.
Set operating modes and parameters of laser radiation by the buttons
SA1-SA9 A2 keyboard unit, which are displayed on the display unit and the display A1
served on the block A3 management, providing the parameters of the laser control
radiation. A4 a power supply for supplying stabilized voltages to
blocks, boards, and elements of the apparatus. You can control power
radiation using a photodiode "CONTROL".
After setting the required parameters of the radiation power and duration,
modulation and pressing the START button, a signal is generated resolution laser.
The radiation is switched off after a set duration. Turning off the machine
CHAIN, set the switch on the side of the unit in position
"0" 7. GETTING STARTED
7.1 Install the unit at a distance of no more than 1.0 m from the wall outlet.
7.2 Set the NETWORK switch to "0".
7.3 Connect the power cord to a wall outlet of 220 V.
7.4 Connect outrigger handle "BPB" or "VRIP" to the front connector
panel.
Attention! When you turn off the reclosing device is made
not less than 3 seconds.
8. OPERATION
8.1 When you turn on the power using the switch on the front panel NETWORK
the device in position "1" on the display shows: "Head №121003», the year ( "12" -2012g.) and
quarter ( "1") of release, "003" serial number; visible light wavelength spectrum
"405-700nm" with "BPB" remote turn on the handle or the length of infrared waves
DC "701-1050nm" light when the remote handle "VRIP"
(Start menu) (Appendix 4). When you press any button except the POWER button Δ
or the display shows: TIME "00:00"; DOSE "00.00"; Part of the "00.0" (general
menu) (Appendix 4).
The initial menu is set after turning off the machine and its re
inclusion.
8.2 Setting the parameters "B" or "SP" radiation.
When the remote handle "BPB" set parameters "B" of the radiation.
When the remote handle "VRIP" set parameters "FE" radiation.
8.2.1 Installing the power of "B" emission (Annex 4):
Turn the handle outrigger "BPB"
a) briefly press the POWER button, and the displayed reading
POWER ▀% - 5 mW (typed) - 000 mW (controlled);
b) briefly press the POWER button Δ, while steps
increasing evidence of power "in the" laser, is shown on the display:
▀% -05mVt, ▀ ▀% -10mVt,
▀ ▀% -15mVt, ▀ ▀ ▀% -20mVt,
▀ ▀ ▀% -25mVt, ▀ ▀ ▀ ▀% -30mVt,
▀ ▀ ▀ ▀% -35mVt, ▀ ▀ ▀ ▀ ▀% -40mVt,
▀ ▀ ▀ ▀ ▀% -45mVt, ▀ ▀ ▀ ▀ ▀ ▀% -50mVt;
c) briefly press the POWER button , while steps
reduced laser power readings;
d) Press the START button and insert the end of the handle in the external photodiode jack
"CONTROL" and monitor the amount of power;
d) Press the STOP button.
8.2.2 Installing the power "FE" radiation:
Turn the handle outrigger "VRIP"
a) briefly press the POWER button, and the displayed reading
POWER ▀% - 10 mW (typed) - 000 mW (controlled);
b) briefly press the POWER button Δ, while steps
Increases Power "SP" laser readings displayed on the display:
b) briefly press the POWER button Δ, while steps
increasing the laser power readings, the display shows:
▀% -10mVt, ▀ ▀% -20mVt,
▀ ▀% -30mVt, ▀ ▀ ▀% -40mVt,
▀ ▀ ▀% -50mVt, ▀ ▀ ▀ ▀% -60mVt,
▀ ▀ ▀ ▀% -70mVt, ▀ ▀ ▀ ▀ ▀% -80mVt,
▀ ▀ ▀ ▀ ▀% -90mVt, ▀ ▀ ▀ ▀ ▀ ▀% -100mVt;
c) briefly press the POWER button , while steps
reduced laser power readings;
d) Press the START button and insert the end of the handle in the external photodiode jack
"CONTROL" and monitor the amount of power;
d) Press the STOP button.
8.2.3 Installing the modulation of the radiation:
If you press any button on the display shows: TIME "00:00"; DOSE
"0.00"; Part of the "0.0" (the general menu)
a) the indicator is displayed part of the "0.0";
b) a short press FREQUENCY Δ, thus increasing
reading tenths of Hz modulation;
c) briefly press the CLOCK button , thus decreasing readings
tenths of Hz;
d) Press and hold FREQUENCY Δ, with increasing evidence
units and tens Hz modulation;
d) Press and hold the CLOCK button , thus decreasing readings
units and tens Hz modulation.
8.2.4 Installation of the radiation duration:
a) the indicator is displayed TIME "00:00";
b) a short press TIME Δ, with increasing evidence
units and tens of seconds;
c) briefly press the TIME button , thus decreasing readings
units and tens of seconds;
d) Press and hold TIME Δ, with increasing evidence
units and tens of minutes;
d) Press and hold the TIME button , thus decreasing readings
units and tens of minutes;
e) Press the START button and carry out the procedure in accordance with the recruited
parameters.
8.3 The end of the procedure is carried out after a preset time or
pressing the STOP button.
8.4 Resetting the dose, frequency by pressing the STOP / RESET button
in the STOP state. Resetting TIME by pressing the STOP / RESET button
in the STOP state after pressing TIME TIME or delta Δ.
8.5 The display is controlled by the radiation dose D = x Rnabrannaya Tprotsedury
(J = W × s).
8.6 Set the NETWORK unit to the "0" position.
Attention! While working with the laser radiation is prohibited to work without
goggles! Avoid direct eye exposure radiation.
OBEREZHNO! KLAS 3R, apparently
TA invisible laser VIPROMІNENNYA,
KOLI VІDKRITE NOT Divit At beam
Attention! Emergency Power Off is performed by
to "0" NETWORK switch on the side panel of the electronic unit.
Attention! When you turn off the reclosing device is made
not less than 3 seconds.
Attention! Storage box packaged produce in accordance with the
deposited handling marks.
The items will be shipped on second - third day after payment by registered priority airmail.
Delivery typically takes 10 to 14 days (about a week for Europe).
If you want to use other methods of shipment email to me.
ALL international
buyers are Welcome!
The shipping is flat for all world:
FREE SHIPPING WORLDWIDE
WE WILL COMBINE
MULTIPLE WINS TO SAVE ON SHIPPING
Guarantee of qualitative packing
30 days guarantee:
We guarantee you complete satisfaction with all my products.
If you receive an item you did not
order or if an item you ordered is received damaged or defective.
We will refund you the price you paid for it or replace it with identical
one. We accept returns in U.S.A.
Item for returning must have the original tags and packing, otherwise it
won't be accepted.
Thanks and good luck!
More from this vendor
Reviews
Shipping and Policies
This store is integrated with the Western Bid™ e-commerce platform, and Western Bid, Inc. is the Merchant of Record for all purchases made in this store. Therefore, you will see "WESTERN BID" listed as the payee on your PayPal account and credit card statement.
I accept PayPal or Credit Cards only.
• Your items will be made and shipped only after the payment is cleared.
• If you don't have Paypal account and would like to pay with your Credit Card, check this step-by-step tutorial on PayPal:
https://www.paypal.com/webapps/mpp/pay-online
Your order will be shipped only after the payment is cleared. This means if you pay via Paypal e-checks there could be delay in 3-5 business days. You can check the status of your payment in your Paypal account or in the correspond invoice here on Lavky.
All the items in the order will be securely packed and shipped within 1-3 working days of payment.
Some items may take longer. If the processing time is more than 7 days, it is clearly stated in the product description.
Delivery Address:
• Please make sure your shipping address is correct at the checkout.
We will ship your order to the address specified on Lavky.com checkout, and not to the address specified on Paypal.
Terms of Delivery
We always ship parcels with a tracking number. We will update you on the tracking number once your order has been prepared and shipped.
Usually delivery takes between one a half and four weeks.
Please note that delivery times may vary depending on your location and customs clearance, so we cannot guarantee the exact time of arrival.
Here are the approximate delivery times:
- USA: 1.5 - 2.5 weeks
- Canada: 2-3 weeks
- Europe: 1-2 weeks
- Australia: 2-3 weeks (sometimes longer, depending on Australian customs)
- The rest of the world: 2-3 weeks
Delivery method
We ship all the parcels from Ukraine (from our logistics centers in Kyiv and Chernivtsi) via international services (FedEx, UPS) in two stages.
First a parcel is sent by express delivery service to Europe, and then, it is shipped by air mail to the United States, Canada or Europe.
You can see the movement of the parcel by a tracking number only in the second stage - 4-6 days after sending your order from our center. We estimate the delivery time to 12-18 days.
Express delivery is available only on individual request. Please contact us if you need Express delivery before placing an order so we can update shipping options.
Customs duties and taxes
Customers are responsible for any fees, taxes and duties related to delivery and ordering products to their country of destination.
Packaging
Your order will arrive in a safe cardboard box, with due packaging and protection from damage.
I want my clients to be happy, so let me know if you have any problems.
If you are not satisfied with your items / service for any reason, please contact me with the problem before leaving a feedback.