SUPPORT UKRAINIAN SELLERS BY SHOPPING HERE!

Lighting

Automatic lighting system for steps of the ladder "SmartStairway SS-26" The new model is a set of automatic LED backlight stairs allows you to connect up to 26 steps of stairs.   Now you can use as a pyroelectric infrared sensors and ultrasonic rangefinders, in any combination, as you need. Version 3.12.   Additions in this version: - Added blocking of polling of pyroelectric sensors for powering up the system for 90 seconds. This allows you to avoid erroneous light on the stairs as a result of erroneous operations of the pyroelectric sensors during their heating during the first 90 seconds after turning on the power. Now you can use timers with the system, smart sockets compatible with Google House, Amazon Alexa and other systems requiring a complete power off of the system. Now the system will not cause false inclusions. - Added the ability to dimming all steps in 8% increments in the range from 20% to 100% brightness. The brightness of the attendants (first and last steps), as before, is adjusted separately in the range from 0 to 100% - Added system reset function to default settings. If you unconsciously changed the settings and do not know what and why you changed, you can return the system to the default settings. Read more in the user manual. The controller for an automatic lighting of stairways by means of low-power LED light sources. One controller is able to provide coverage of from 4 to 26 stages. The controllers have the ability to enable consistent, which allows to increase the possible number of steps almost to infinity. The system provides a flexible configuration for any customer requirements. The controller can be used in conjunction with a light sensor, or without it, with passage switches simple pyroelectric (infrared) and digital sensors to ensure smooth movement series circuit when the signal from the sensors in the direction of movement of people included on the ladder. The controller has a customizable interface and intuitive settings available. Easy to install.    The controller is made in a plastic case that can be mounted on DIN-rail or attached to the surface by means of screws or screws. (see photo)   User Guide in English can be downloaded here   https://shop.xopc.net.ua/files...   ,  https://shop.xopc.net.ua/files...   -  PIR Sensors manual (copy the URL and paste it into your browser for downloading)   Specifications 1. The number of channels (the number of connected steps)  4...  26 pcs. 2. DC supply voltage of   12-24V. (The input voltage is DC 8-25V. Depending on the required voltage for your fixtures)  3. The maximum current load on one channel  (per steps)   I nom. 0.4A  (I max 0.5A)     (4.8 W for luminaires 12V ; 9.6W for lighting fixtures 24V.) 4.  Sensing elements  - PIR digital sensors, or ultrasonic rangefinder.  - digital photo sensor  (unboxing ). 5. Power Digital Sensor outputs:      DC 5V 6. Protection IP20 (indoors, not waterproof) 7. Ambient temperature   -5 ... + 50`C 8. Controller Case Dimensions   115x90x41 mm 9. Controller Power Consumption standby time (up to):  0,3W. 10. Power consumption controller under load (max):   3,5W 11. The maximum total allowable load capacity (max):  If Vinput = 12V - 125 W. (max 156W) If Vinput = 24V - 250 W. (max 312W)                                                                  The kit, depending on the option you choose, includes: (The kits do not include a  power supply  and lights or LED stripes. The power supply should be selected based on the power and the number of steps you use. You can choose LED lamps or LED strips based on your tastes and desires, but make sure that the power of each step is not more than 400 mA.)  "PIR standard" KIT:        -Controller SS-26 - 1 pc.       - Pyroelectric sensors PIR-SR501 - 2 pcs.       - Light sensor - 1 pc.       - Box, user manual.   The main advantages of the system .   1. Small body size and its convenient mounting  embedded and external boxes. 2. Digital motion sensors in the standard wiring boxes.   3. External light sensor allows you to choose the installation location with a constant light level is not dependent on or off lighting stairs or more light sources.   4. Easy and intuitive customization system.   5. Adjustable "light duty" first and last steps of a ladder.   6. Ability to connect through passage switch for lighting control at any time, regardless of the lighting conditions.   7. Low power consumption.   8. Long service life of LED light sources (tape or spotlights).   9. Easy installation and operation.   The algorithm of the system        When the sensor has exposed the movement, the staircase lights are illuminated in the direction of the person's movement at the speed set in the system settings. After the waiting time has elapsed, the illumination of the steps set in the system settings is switched off in the reverse order. If during the illumination of the entire ladder the sensor detects motion, then the timer is reset to zero and the time until the light is turned off is considered from the moment when the sensor ceases to see the movement of people on the stairs.  If the movement on the stairs on the other side is detected while the backlight is on, the illumination is switched on in both directions. It also turns off in the reverse order. If you press the "Down" or "Up" button, the backlight turns on from the pressed button and will be on until either of these buttons is pressed. The operation of the sensors is not taken into account. The "up" and "down" buttons on the controller are connected to the digital inputs of the controller "Up button" and "Down button". To these inputs you can connect additional buttons without fixing. For example, buttons for doorbells. See the diagram of the connection in the PDF file, the link to which you will find below. Additional buttons are not included.       Using a light sensor.   The controller can be used as a light sensor and without it. When connected to the controller light sensor should activate its use (claim 1. Setting) or deactivated when not using the sensor. The sensor should be installed in such a place that it would not be reached by light from indoor lighting and the lighting levels themselves. Digital sensor delivers a logic controller port 0 when the lighting is not sufficient or logical unit if the light level is less than the set limit. When the lighting is activated by light duty first and last stages and the controller is allowed to turn on the backlight levels for the signals from motion sensors depending on the selected algorithm (see. Above). When driving on the stairs when the backlight is switched on or suddenly steps onto the sensor light gets brighter light controller activation threshold - the staircase lights and duty levels off and the controller will go into standby mode. Job motion sensors and processing of people on the stairs counters maintained even when the lights on the signal light sensor is not implemented.   Using the motion sensor.   The controller allows you to connect any motion sensors, which you need. It can be both pyroelectric or ultrasonic. You can connect both sensors of the same type or a single pyroelectric and ultrasonic in any combination. The default factory setting for the width of the stairs of the ultrasonic sensor is set equal to 0.8 meter. The movement will be determined if the distance to the obstacle is reduced by more than 10 cm. Measurements of ultrasonic sensors are carried out by calculating the average value of 5 measurements, that virtually eliminates false positives when using ultrasonic sensors. If necessary, you can easily change the width of the stairs through the controller setup menu in step 7. Details can be found in the user manual URL: https://shop.xopc.net.ua/files...   Note!  Ultrasonic sensors have certain technological shortcomings. Their principle of operation is based on the reflected high frequency sound. Therefore, ultrasonic sensors can not detect an obstacle if a person is dressed in a sound-absorbing clothes and have a certain delay in the work, because return time of the sound wave takes from 50 to 500 Milis We recommend used pyroelectric sensors, whenever possible. The use of ultrasonic  sensors is justified only when the staircase has no handrail or banister is delicate and next to the stairs is communicating zone through which people move and it may cause false triggering of illumination ladder pyroelectric sensors.To connect the ultrasonic sensor to use a shielded twisted pair wire with a cross section view of the length of the wire, but not less than 0.5 mm. square (AWG20). Braided shield is recommended to ground. It is recommended to avoid the length of more than 10m. If the wire is longer than 10m, should be applied thicker wire.     Ultrasonic sensors are not recommended to be installed at a distance of 50 cm from the floor or wall as this may cause false switching on the system.     The presence of other ultrasound sources in the sensor area may cause erroneous triggering.       Also note that ultrasonic rangefinders are capable of measuring distances of not more than 1.5 meters. If the distance to the reflective surface is very large or there is no such surface at all in front of the sensor, the sensor causes the backlight to be delayed for each stage for about 1 second. In such cases, you should try to pick up the installation site so that the sensor can see what kind of close-lying wall or obstacle or refuse this type of sensor.       Important. Dear buyer. All products sent to you are tested on the stand for at least 72 hours. Also, before shipping the entire kit is tested for all functions and ports. After testing, the product is packed and shiping to you. After shiping, I provide you with a link to Youtube with a video report of checking and packaging your product (the video on YouTube is saved as confidential information and is only viewable to you). This allows you to completely exclude possible hidden defects, as well as disputes on health issues or product conformance. You can be sure that you get exactly what you see in the photo and video.    Please be very careful when connecting the product. First, mount the step lights and check the performance of each step separately by connecting them to the power source. Keep in mind that the power of the luminaires of one step does not exceed 0.4A (when the voltage of the luminaires is 12V - 5W, at a voltage of 24V - 10W). Exceeding the power of the fixtures or closing the wires of fixtures or LED strips will result in the failure of the output keys of the system. Check the polarity of the wires and sensors connected to the inputs carefully. Violation of the polarity or wrong connection of wires to the inputs can lead to the destruction of the microprocessor of the system and its failure. To the output + 5V only sensor power can be connected. The maximum load power to be connected to the "+ 5V" output must not exceed 500mA. Any damage to the product that may occur during improper connection or violation of the usage rules is not guaranteed and claims for them are not accepted. If you have any questions about the connection, ask them to me. I will gladly answer your questions. It is better to ask a question before the connection starts, as this will save a lot of time and effort, and also will save your ladder in good condition.   A detailed video guide to connecting and configuring the system is available at the following link to YouTube. Connecting LED strips or LED lighting fixtures. First step. First, mount the LED strip. Connect all "+" clips to one lead to the "+" terminal of the power supply. Then manually alternate and one-by-one connect the "-" wire from each step to the "-" terminal of the power supply. Make sure that all steps work correctly and there is no wire shortage. Also, make sure that there is no problem in the soldering points of the LED strips. If the tapes are mounted on a metal base, pay attention that the tapes do not close on the ground. Only convinced that everything is assembled and connected correctly and the power of one step does not exceed 0.4A (for a voltage of 12V nominally 4.8W, maximum permissible 5W.) Go The second step. - Disconnect the power supply from the mains. Connect the test leads from the steps to the corresponding wires of the controller outputs. Note that the first step is connected to the "Out01" output, and the last step to the "Out26" output. The second step to "Out02", the third to "Out03" and so on. If you use fewer steps than 26, the last step is still connected to the "Out26" output. After connecting all the steps and checking the correct connection of the wires and isolating them, you can turn on the power supply. Note that shorting the wires "+" and "-" of the LED strip will result in exceeding the permissible power of one step and failure of the output on which there was a short circuit or even all groups of 7 steps of the chip on which there was a short circuit. Please be careful. In this case, the first and last steps will be put on standby. By pressing the "Up" button "Down" you can check the LED strip lights. After that, turn off the power supply and connect the sensors according to the user's manual. Then turn on the system and adjust the number of steps you need. By default, the use of all 26 steps is enabled. If you use fewer steps and have not adjusted the number of steps used, then when you enter from the top of the step "Out26" to the next one, there will be a large delay in time during which the controller will include unused steps. For ultrasonic sensors, the quality of the wires used is important. This should be a twisted pair of 0.5mm. square is necessarily shielded. Also, ultrasonic sensors may not work correctly when using sound-absorbing clothing or coatings. All features of ultrasonic sensors are described on the product page and in the user's manual. Frequently Asked Questions - Can I use a system with a 5V DC power supply? The system is designed to operate with a supply voltage of 8 to 25V DC. Working with power supplies and luminaires with a voltage different from the specified can cause damage or not stable operation of the system. - What kind of lamps can I use? The system is designed to be used in conjunction with dimmable LED lights or LED stripes with a voltage of 12 or 24 VDC. The current of the luminaires or LED strips should not exceed 0.4A (0.5A maximum, taking into account the resistance of the wires at the point of connection to the controller) for one step. Exceeding the current will lead to system failure. So for one step, the maximum power of luminaires with a supply voltage of 12V DC is 12V * 0.4A = 4.8W; with a supply voltage of 24V DC 24V * 0.4A = 9.6W. If you want to use spotlights with powerful LEDs and a driver stabilizing the current for each fixture, then consider that such drivers do not work well with PWM modulation of the brightness of the fixtures. These drivers do not provide a smooth brightness change in 128 steps, which the controller provides and switching on comes in jumps of 5-6 steps. As a result, you will turn on the steps by blinking, and you will not succeed in achieving smoothness. It is better to use luminaires with several SMD LEDs and resistors without a power driver, which work well with PWM brightness control. For how certain lamps work with PWM, consult their seller or manufacturer. - I want to use LED stripes. What type and length can I connect to one step. Data on the possibility of using different LED stripes, see the table: LED Type (LED CHIP) Number of LEDs per 1 meter Supply voltage of LED strip Power consumption per 1 meter of LED strip (W / m) Current strength per 1 meter of LED strip Maximum allowable length of LED strip for one step SMD 3528 60 12 V DC 4.8 W/m 0.4A 1 m (3'3.37") SMD 3528 120 9.6 W/m 0.8A 0.5m (1'7.685") SMD 3528 60 24V DC 4.8 W/m 0.2A 2 m (6'6.74") SMD 3528 120 9.6 W/m 0.4A 1 m (3'3.37") SMD 5050 30 12V DC 7.2 W/m 0.6 A 70 cm (2'1.591") SMD 5050 60 14.4 W/m 1.2A 35 cm (1'1.78") SMD 5050 30 24V DC 7.2 W/m 0.3A 1.4m (4'3.181") SMD 5050 60 14.4 W/m 0.6A 70 cm (2'1.591") SMD 3014 120 12V DC 12 W/m 1A 40 cm (1'3.748") SMD 3014 240 24 W/m 2A 20 cm (7.874") SMD 3014 120 24V DC 12 W/m 0.5A 80 cm (2'7.496") SMD 3014 240 24 W/m 1A 40 cm (1'3.748") SMD 335 60 12V DC 4.8W/m 0.4A 1 m (3'3.37") SMD 335 60 24V DC 4.8W/m 0.2A 2 m (6'6.74") SMD 5630 60 12V DC 14.4 W/m 1.2A 35 cm (1'1.78") SMD 5630 60 24V DC 14.4 W/m 0.6A 65 cm (2'1.591") !!! LED stripes on SMD2835 - Not recommended for use. (The reason is that SMD2835 LEDs have a power of 0.2, 0.5, 1W
Vendor: XOPC NET UA
$81.00